All Categories

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
Reactive power compensation device
Home> Products> Reactive power compensation device

VSKAPF/SVG Active Power Filter Static Var Generator

Key Features

  • Flexible Compensation Modes:Supports multiple compensation modes with comprehensive power quality management capabilities.
  • Bidirectional Reactive Power Compensation:Enables dynamic bidirectional reactive power regulation and improves power factor to 0.99.
  • Ultra-Fast Response:Delivers rapid dynamic compensation with a response time of ≤20 ms.
  • 7-Inch Centralized Monitoring:Supports an external 7-inch touchscreen HMI for intuitive operation and real-time power quality monitoring.
Product Description

Product Overview

The APF/SVG collects current signals in real time via external CTs and sends them to the signal conditioning circuit, which forwards the processed signals to the controller. The controller decomposes the sampled currents to extract harmonic currents of each order, reactive currents and three-phase unbalanced currents. It compares the collected current components to be compensated with the compensating current already output by the APF/SVG to obtain the deviation value. This value is sent as a real-time compensation signal to the drive circuit, triggering the IGBT converter to inject compensating current into the power grid. Closed-loop control is thereby implemented to realize the compensation function.

Technical Parameters

Category

Item

Indicators

Input

Operating Voltage

400V (-20% ~ +20%); 690V (-20% ~ +20%)

Operating Frequency

50Hz (-10% ~ +10%)

Current Transformer

1000:5 ~ 10000:5

Functions

Harmonic Compensation

SVG: 2–13th (50% of rated current)

APF: 2–50th

Harmonic Filtering Rate

≥90% ≥85% within equipment capacity (Load current distortion rate ≥20%); ≥70% (Load current distortion rate <20%)

Reactive Power Compensation

-1 ~ +1 adjustable (within equipment capacity)

3-phase Unbalance Compensation

100% unbalance full compensation (690V model has no 3-phase unbalance compensation function)

Communication Protocol

Communication Mode

RS485, Modbus Protocol

Communication Interface

RS485

Upper Computer Software

Available; all parameters configurable via upper computer

Fault Alarm

Available; up to 500 fault alarm records

Monitoring

Independent module monitoring / centralized whole-unit monitoring supported

Technical Index

Full Response Time

≤10 ms

Active Power Loss

≤2.5%

Cooling Method

Intelligent Air Cooling

Noise Level

≤60 dB

Protection Functions

Overvoltage, undervoltage, overheat, overcurrent, short-circuit and more than 20 types of protection

CT Installation Position

Load side / Grid side optional

Mechanical Characteristics

Wall-mounted Cabinet Size

Same as module dimensions for wall-mount type

Module Weight

13kg (35A/30kvar); 24kg (75A/50kvar); 8kg (100A/150A/100kvar); 45kg (200A/150kvar)

Color

7035 fine texture powder coating

Environmental Requirements

Operating Temperature

-10°C ~ +50°C

Altitude

<5000 m (Above 1000 m, power derating 1% per additional 100 m)

Relative Humidity

<95%, non-condensing

Wiring Drawing

16 1.png16 2.png

Service Conditions

Ambient temperature: -10°C ~ +50°C

Altitude: ≤5000 m, 1% power derating per 100 m over 1000 m

Relative humidity: <95%, non-condensing

Voltage range: 400V / 690V (-20% ~ +20%)

Frequency: 50Hz (-10% ~ +10%)

Installation: Indoor, free of explosive/corrosive media

Protection: Module IP20+, electronics IP42; IP54 optional

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000