Reactive power compensation device
Domus> Producta>Reactive power compensation device

VSKAPF/SVG Active Power Filter Static Var Generator

Proprietates Claves

  • Modi Compensatorii Flexibiles : Supportat varios modos compensationis cum capacitibus comprehensivis administrationis qualitatis potentiae.
  • Compensatio Potentiae Reactivae Bidirectionalis : Facilitat regulatonem dynamicam potentiae reactivae bidirectionalem et meliorat factorem potentiae ad 0.99.
  • Responsio ultra-rapida — Deliverit compensatio dynamicam celerem cum tempore responsionis ≤20 ms.
  • monitorium Centrale 7-pollicare — Supportat externum HMI tactilis 7-pollicare pro operatione intuitiva et monitoratione qualitatis potentiae in tempore reali.
Descriptio Producti

Product Overview

The APF/SVG collects current signals in real time via external CTs and sends them to the signal conditioning circuit, which forwards the processed signals to the controller. The controller decomposes the sampled currents to extract harmonic currents of each order, reactive currents and three-phase unbalanced currents. It compares the collected current components to be compensated with the compensating current already output by the APF/SVG to obtain the deviation value. This value is sent as a real-time compensation signal to the drive circuit, triggering the IGBT converter to inject compensating current into the power grid. Closed-loop control is thereby implemented to realize the compensation function.

Parametri technici

CATEGORIA

Res

Indicatores

Input

Voltage Operativum

400V (-20% ~ +20%); 690V (-20% ~ +20%)

Operating Frequency

50Hz (-10% ~ +10%)

Transformator curae

1000:5 ~ 10000:5

Functiones

Compensatio Harmonica

SVG: 2–13a (50% of rated current)

APF: 2–50a

Ratio Filtrationis Harmonicorum

≥90% ≥85% within equipment capacity (Load current distortion rate ≥20%); ≥70% (Load current distortion rate <20%)

Compensātiō Potestātis Reactīvae

-1 ~ +1 adjustable (within equipment capacity)

3-phase Unbalance Compensation

100% unbalance full compensation (690V model has no 3-phase unbalance compensation function)

Protocollo communicationis

Modus communicationis

RS485, Modbus Protocol

Interface Communicationis

RS485

Upper Computer Software

Available; all parameters configurable via upper computer

Admonitio Defectus

Disponibilis; usque ad 500 recordationes admonitionum defectuum

Monitoratio

Monitorium moduli independentis / monitorium centralis totius unitatis suadetur

TECHNICAL INDEX

Tempus Responsionis Plenum

≤10 ms

Amissa potentiae activae

≤2.5%

Modus refrigerationis

Intelligentes aeris refrigerationem

Gradus strepitus

≤60 dB

Functiones protectionis

Supervoltatio, subvoltatio, supercalefactio, supercurrentia, curtus circuitus et plus quam 20 typi protectionis

Locus Installationis CT

Lateralis oneris / lateralis rete optabilis

Caracteristica Mechanica

Dimensio Armarii Muris Affixi

Eadem ut dimensiones moduli pro typis muris affixis

Pondus Moduli

13 kg (35A/30kvar); 24 kg (75A/50kvar); 8 kg (100A/150A/100kvar); 45 kg (200A/150kvar)

Color

7035 fina teksturo pulvora pokovro

Postulationes environmentalis

Temperatura operativa

-10°C ~ +50°C

Altitudo

<5000 m (Supra 1000 m, potencio reduktas 1% pro ĉiu aldonaj 100 m)

Humiditas relativa

<95%, ne kondensanta

Dispositio electrica

16 1.png16 2.png

Status servitii

Ambienta temperaturo: -10°C ~ +50°C

Alteco: ≤5000 m, 1% potencoreduktado pro ĉiu 100 m super 1000 m

Relativa humideco: <95%, ne kondensanta

Tensio-intervalo: 400V / 690V (-20% ~ +20%)

Frekvenco: 50Hz (-10% ~ +10%)

Instalo: Ena, sen eksploda/koroda medio

Protekto: Modulo IP20+, elektroniko IP42; IP54 opciebla

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Nomen societatis
Nuntius
0/1000

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Nomen societatis
Nuntius
0/1000

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Nomen societatis
Nuntius
0/1000