Asosiy xususiyatlar
Mahsulotga umumiy nazar
Ushbu filtrlash reaktori yuqori va past kuchlanishli filtrlash shkafalarida qo'llaniladi. U filtrlash kondensatorlari bilan ketma-ket ulanadi va elektr tarmog'ida mos chastotali garmoonik toklarni yutish uchun aniq rezonans chastotasiga sozlanadi. Past kuchlanishli elektr tarmoqlarida to'g'rilagichlar, konvertorlar va chastota o'zgartirgichlar kabi ko'plab garmoonik manbalari mavjud. Hosil bo'lgan yuqori tartibli garmooniklar tizimdagi asosiy transformator va boshqa elektr jihozlari xavfsiz ishlashini jiddiy ravishda xavf ostiga qo'yadi. Filtrlash reaktori kondensatorlar bilan ketma-ket ulanganda u faqat tarmoqdagi garmoonikalarni samarali ravishda yutib qolmaydi, balki tizimning quvvat koeffitsientini ham yaxshilaydi va elektr tizimining xavfsiz ishlashida muhim rol o'ynaydi.
Texnik parametrlar
Model |
Mos kondensator sig'imi (kVAR) |
Reaktorning sig'imi (kVAR) |
Joriy(A) |
Индуктивлик (мH) |
Hajm(L*W*H) |
Izolyatsiya sinfi |
CKSG-0.610.45-6% |
10 |
0.60 |
12.83 |
3*3.87 |
190*160*170 |
H |
CKSG-0.9/0.4-6% |
15 |
0.90 |
19.24 |
3*2.58 |
190*170*170 |
H |
CKSG-1.2/0.45-6% |
20 |
1.20 |
25.66 |
3*1.94 |
190*170*170 |
H |
CKSG-1.5/0.45-6% |
25 |
1.50 |
32.07 |
3*1.55 |
230*150*190 |
H |
CKSG-1.8/0.45-6% |
30 |
1.80 |
38.49 |
3*1.29 |
230*160*190 |
H |
CKSG-2.4/0.45-6% |
40 |
2.40 |
51.31 |
3*0.97 |
230*170*190 |
H |
CKSG-3.0/0.45-6% |
50 |
3.00 |
64.14 |
3*0.77 |
265*210*230 |
H |
76.97CKSG-3.6/0.45-6% |
60 |
3.60 |
76.97 |
3*0.65 |
265*210*230 |
H |
CKSG-0.7/0.45-7% |
10 |
0.70 |
12.83 |
3*4.52 |
190*160*170 |
H |
CKSG-1.05/0.45-7% |
15 |
1.05 |
19.24 |
3*3.01 |
190*170*170 |
H |
CKSG-1.4/0.45-7% |
20 |
1.40 |
25.66 |
3*2.26 |
230*150*190 |
H |
CKSG-1.75/0.45-7% |
25 |
1.75 |
32.07 |
3*1.81 |
230*160*190 |
H |
CKSG-2.1/0.45-7% |
30 |
2.10 |
38.48 |
3*1.51 |
230*170*190 |
H |
CKSG-2.8/0.45-64.147% |
40 |
2.80 |
51.31 |
3*1.13 |
230*180*190 |
H |
CKSG76.97-3.5/0.45-7% |
50 |
3.50 |
64.14 |
3*0.90 |
265*220*230 |
H |
CKSG-4.2/0.45-7% |
60 |
4.20 |
76.97 |
3*0.75 |
265*220*230 |
H |
CKSG-1.4/0.525-14% |
10 |
1.40 |
11.00 |
3*12.29 |
230*150*190 |
H |
CKSG-2.1/0.525-14% |
15 |
2.10 |
16.49 |
3*8.19 |
230*170*190 |
H |
CKSC-2.8/0.525-14% |
20 |
2.80 |
21.99 |
3*6.15 |
230*180*190 |
H |
CKSG-3.5/0.525-14% |
25 |
3.50 |
27.49 |
3*4.92 |
265*220*230 |
H |
CKSG-4.2/0.525-14% |
30 |
4.20 |
32.99 |
3*4.10 |
265*220*230 |
H |
CK50SG-5.6/0.525-14% |
40 |
5.60 |
43.98 |
3*3.07 |
265*240*230 |
H |
CKSG-7.0/0.525-14% |
50 |
7.00 |
54.98 |
3*2.46 |
290*190*280 |
H |
CKSG-8.4/0.525-14% |
60 |
8.40 |
65.98 |
3*2.05 |
290*210*280 |
H |
Ulanish sxemasi

Xizmatlashish shartlari
Balandlik — 1000 metrdan oshmasin.
Ishlash temperaturasida — -25°C dan +45°C gacha, nisbiy namlik 90% dan oshmasin.
Atrof muhitda zararli gazlar, yonuvchi yoki portlovchi moddalar bo'lmasin.
Atrof muhit yaxshi ventilyatsiyaga ega bo'lishi kerak. Agar kabinet ichiga o'rnatilsa, qo'shimcha ravishda ventilyatsiya jihozi ta'minlanadi.