Manyan siffofi
Rubutun Product
Wani wannan filter reactor yana amfani da shi a cikin high da low voltage filter cabinets. Ya kashe da filter capacitors a karamin, kuma yana tunawa zuwa wani specific resonant frequency don gane harmonic currents na frequencies na farko a power grid. Low-voltage power grids suna da mahailloli na harmonic masu ƙarfi kamar rectifiers, converters, da frequency converters. Harmonics na farko da suka dace su zama tushen da safe operation na main transformer da wani electrical equipment na farko a cikin system. Idan filter reactor ya kashe da capacitors, zai iya gane harmonics na grid da kuma taimaka wajen sauyin power factor na system, wanda ke taimakawa sosai a safe operation na power system.
Ƙididdigar fasaha
Samfur |
Matsaloli na capacitor capacity (KVAR) |
Capacitance na reactor (KVAR) |
Current(A) |
Inductance (mH) |
Hajarin(L*W*H) |
Ƙungiyar rufi |
CKSG-0.610.45-6% |
10 |
0.60 |
12.83 |
3*3.87 |
190*160*170 |
H |
CKSG-0.9/0.4-6% |
15 |
0.90 |
19.24 |
3*2.58 |
190*170*170 |
H |
CKSG-1.2/0.45-6% |
20 |
1.20 |
25.66 |
3*1.94 |
190*170*170 |
H |
CKSG-1.5/0.45-6% |
25 |
1.50 |
32.07 |
3*1.55 |
230*150*190 |
H |
CKSG-1.8/0.45-6% |
30 |
1.80 |
38.49 |
3*1.29 |
230*160*190 |
H |
CKSG-2.4/0.45-6% |
40 |
2.40 |
51.31 |
3*0.97 |
230*170*190 |
H |
CKSG-3.0/0.45-6% |
50 |
3.00 |
64.14 |
3*0.77 |
265*210*230 |
H |
76.97CKSG-3.6/0.45-6% |
60 |
3.60 |
76.97 |
3*0.65 |
265*210*230 |
H |
CKSG-0.7/0.45-7% |
10 |
0.70 |
12.83 |
3*4.52 |
190*160*170 |
H |
CKSG-1.05/0.45-7% |
15 |
1.05 |
19.24 |
3*3.01 |
190*170*170 |
H |
CKSG-1.4/0.45-7% |
20 |
1.40 |
25.66 |
3*2.26 |
230*150*190 |
H |
CKSG-1.75/0.45-7% |
25 |
1.75 |
32.07 |
3*1.81 |
230*160*190 |
H |
CKSG-2.1/0.45-7% |
30 |
2.10 |
38.48 |
3*1.51 |
230*170*190 |
H |
CKSG-2.8/0.45-64.147% |
40 |
2.80 |
51.31 |
3*1.13 |
230*180*190 |
H |
CKSG76.97-3.5/0.45-7% |
50 |
3.50 |
64.14 |
3*0.90 |
265*220*230 |
H |
CKSG-4.2/0.45-7% |
60 |
4.20 |
76.97 |
3*0.75 |
265*220*230 |
H |
CKSG-1.4/0.525-14% |
10 |
1.40 |
11.00 |
3*12.29 |
230*150*190 |
H |
CKSG-2.1/0.525-14% |
15 |
2.10 |
16.49 |
3*8.19 |
230*170*190 |
H |
CKSC-2.8/0.525-14% |
20 |
2.80 |
21.99 |
3*6.15 |
230*180*190 |
H |
CKSG-3.5/0.525-14% |
25 |
3.50 |
27.49 |
3*4.92 |
265*220*230 |
H |
CKSG-4.2/0.525-14% |
30 |
4.20 |
32.99 |
3*4.10 |
265*220*230 |
H |
CK50SG-5.6/0.525-14% |
40 |
5.60 |
43.98 |
3*3.07 |
265*240*230 |
H |
CKSG-7.0/0.525-14% |
50 |
7.00 |
54.98 |
3*2.46 |
290*190*280 |
H |
CKSG-8.4/0.525-14% |
60 |
8.40 |
65.98 |
3*2.05 |
290*210*280 |
H |
Tashin kofin

Service Conditions
Fadamar Altitute : ba tare da 1000 m.
Hanyar aiki : -25°C ~ +45°C, kuma tsinkaku na hankali ba tare da 90%.
Babu gas mai tsoro, abu mai yanka ko mai fuskanta a cikin ƙarfi na gaba.
Cikin ƙarfi na gaba ya kamata suka da kariya mai kyau. Idan aka sa a cikin kabo, kariya mai kyau zai bukatar sa a sarki.