Proprietates Claves
Product Overview
Hoc reactorum filtrans in armariis filtrorum ad altam et ad bassam tensionem utitur. In serie cum condensatoribus filtrorum coniungitur, ad certam frequentionem resonantiam sintonizatur, ut currentes harmonicis correspondentibus frequentionibus in rete electrico absorbeat. Rete electricum ad bassam tensionem multas fontes harmonicarum, ut rectificatores, conversores et convertitores frequentiae, continet. Harmonicae ordinis superioris generatae operationem securam transformatoris principalis et aliorum apparatus electricorum in systemate graviter periclitabuntur. Cum reactorum filtrans in serie cum condensatoribus coniungitur, non solum harmonicis retis electrici efficaciter absorbet, sed etiam factor potestatis systematis meliorat, ergo in operatione secura systematis electrici partem vitalem agit.
Parametri technici
Modellum |
Capacitas condensatoris idonea (kvar) |
Capacitas reactoris (kvar) |
Currentem(A) |
Inductantia (mH) |
Magnitudo (L*W*H) |
Insulatio Classis |
CKSG-0.610.45-6% |
10 |
0.60 |
12.83 |
3*3.87 |
190*160*170 |
H |
CKSG-0.9/0.4-6% |
15 |
0.90 |
19.24 |
3*2.58 |
190*170*170 |
H |
CKSG-1.2/0.45-6% |
20 |
1.20 |
25.66 |
3*1.94 |
190*170*170 |
H |
CKSG-1.5/0.45-6% |
25 |
1.50 |
32.07 |
3*1.55 |
230*150*190 |
H |
CKSG-1.8/0.45-6% |
30 |
1.80 |
38.49 |
3*1.29 |
230*160*190 |
H |
CKSG-2.4/0.45-6% |
40 |
2.40 |
51.31 |
3*0.97 |
230*170*190 |
H |
CKSG-3.0/0.45-6% |
50 |
3.00 |
64.14 |
3*0.77 |
265*210*230 |
H |
76.97CKSG-3.6/0.45-6% |
60 |
3.60 |
76.97 |
3*0.65 |
265*210*230 |
H |
CKSG-0.7/0.45-7% |
10 |
0.70 |
12.83 |
3*4.52 |
190*160*170 |
H |
CKSG-1.05/0.45-7% |
15 |
1.05 |
19.24 |
3*3.01 |
190*170*170 |
H |
CKSG-1.4/0.45-7% |
20 |
1.40 |
25.66 |
3*2.26 |
230*150*190 |
H |
CKSG-1.75/0.45-7% |
25 |
1.75 |
32.07 |
3*1.81 |
230*160*190 |
H |
CKSG-2.1/0.45-7% |
30 |
2.10 |
38.48 |
3*1.51 |
230*170*190 |
H |
CKSG-2.8/0.45-64.147% |
40 |
2.80 |
51.31 |
3*1.13 |
230*180*190 |
H |
CKSG76.97-3.5/0.45-7% |
50 |
3.50 |
64.14 |
3*0.90 |
265*220*230 |
H |
CKSG-4.2/0.45-7% |
60 |
4.20 |
76.97 |
3*0.75 |
265*220*230 |
H |
CKSG-1.4/0.525-14% |
10 |
1.40 |
11.00 |
3*12.29 |
230*150*190 |
H |
CKSG-2.1/0.525-14% |
15 |
2.10 |
16.49 |
3*8.19 |
230*170*190 |
H |
CKSC-2.8/0.525-14% |
20 |
2.80 |
21.99 |
3*6.15 |
230*180*190 |
H |
CKSG-3.5/0.525-14% |
25 |
3.50 |
27.49 |
3*4.92 |
265*220*230 |
H |
CKSG-4.2/0.525-14% |
30 |
4.20 |
32.99 |
3*4.10 |
265*220*230 |
H |
CK50SG-5.6/0.525-14% |
40 |
5.60 |
43.98 |
3*3.07 |
265*240*230 |
H |
CKSG-7.0/0.525-14% |
50 |
7.00 |
54.98 |
3*2.46 |
290*190*280 |
H |
CKSG-8.4/0.525-14% |
60 |
8.40 |
65.98 |
3*2.05 |
290*210*280 |
H |
Dispositio electrica

Status servitii
Altitudo : non superat 1000 m.
Temperatura operativa : -25°C ~ +45°C, umiditas relativa non superat 90%.
Nulla gas nocivus, materia flammabilis aut explosiva in ambiente circumstante.
Ambientia circumstante bene ventilata esse debet. Si in armario installatur, apparatus ventilatorius additus praebendus est.