Reaktiv quvvat kompensatsiyasi qurilmasi
Bosh sahifa > Mahsulotlar>Reaktiv quvvat kompensatsiyasi qurilmasi

ACL/OCL seriyali uch fazali kirish va chiqish reaktorlari

Mahsulot tavsifi

Mahsulotga umumiy nazar

Chiqish reaktori garmoonik kuchlanish va garmoonik tokni filtrlash hamda elektr tarmog'i sifatini yaxshilash uchun chiqish terminaliga o'rnatilishi kerak. Bizning kirish va chiqish reaktorlarimiz yuqori sifatli import qilingan silitsiyli po'lat varaqdan va ilg'or ishlab chiqarish texnologiyasi yordamida ishlab chiqarilgan. Ular zich o'lchamga ega, past issiqlik ko'tarilish va past shovqin darajasiga ega.

Bizning kompaniya tomonidan ishlab chiqarilgan reaktorlar Siemens, ABB, Sanken, Hitachi, Toshiba, Panasonic, Yaskawa, Powtran, Danfoss, Fuji, Eurotherm, LG, OMRON, Hyundai, Schneider, Lenze, Emerson va Convotherm kabi xalqaro va mahalliy brendlarning chastota o'zgartirgichlari bilan mos keladi.

Asosiy xususiyatlar

Elektr ta'minoti boshqa jihozlarga aniq ta'sir (shovqin va ortiqcha kuchlanish) ko'rsatadi

Elektr ta'minotining fazalararo kuchlanish nozikligi nominal kuchlanishning 1,8% dan oshib ketadi

Juday qisqa tutashuvli zanjirlar (kuch transformatorining quvvati VFD ning nominal qiymatidan 10 marta ortiq)

Chiziqdagi tokni kamaytirish uchun bitta zanjirga bir nechta VFD o'rnatilgan

Quvvat omilini to'g'rilash kondensatorlari yoki PFC qurilmalari ishlatilmoqda

Texnik parametrlar

VFD quvvati (kVt)

Kirish reaktori turi

Nominal oqim ((A))

Umumiy o'lcham L*E*H (mm)

O'rnatish o'lchami L×E (mm)

Kuchlanish tushishi (%)

Индуктивлик (мH)

Vazn(kg)

2.2

ACL-4.4V/10A

10

155*130*130

80/120x60-Φ8

2%

1.401

3.5

5.5

ACL-4.4V/15A

15

155*130*130

80/120x60-Φ8

2%

0.934

3.6

7.5

ACL-4.4V/20A

20

155*130*130

80/120x60-Φ8

2%

0.701

3.6

11

ACL-4.4V/30A

30

155*130*130

80/120x60-Φ8

2%

0.467

3.7

15

ACL-4.4V/40A

40

155*140*130

80/120x70-Φ8

2%

0.350

5.1

18

ACL-4.4V/50A

50

155*150*130

80/120x80-Φ8

2%

0.280

6.0

22

ACL-4.4V/60A

60

155*150*130

80/120x80-Φ8

2%

0.234

6.1

30

ACL-4.4V/80A

80

190*150*160

80/150x85-Φ8

2%

0.175

9.0

37

ACL-4.4V/90A

90

190*150*-160

80/150x85-Φ8

2%

0.156

9.2

45

ACL-4.4V/120A

120

190*160*160

80/150x95-Φ8

2%

0.117

10.7

55

ACL-4.4V/150A

150

230*150*220

120/180x85-Φ8

2%

0.093

15.6

75

ACL-4.4V/200A

200

230*150*220

120/180x85-Φ8

2%

0.070

16.3

110

ACL-4.4V/250A

250

230*160*220

120/180x95-Φ8

2%

0.056

19.0

132

ACL-4.4V/290A

290

265*180*250

135/200*90-Φ8

2%

0.048

22.0

160

ACL-4.4V/330A

330

265*190*250

135/200*100-Φ8

2%

0.042

26.0

185

ACL-4.4V/390A

390

265*190*250

135/200*100-Φ8

2%

0.036

27.0

220

ACL-4.4V/490A

490

290*160*310

135/200*100-Φ8

2%

0.029

35.1

240

ACL-4.4V/530A

530

290*160*310

135/200*100-Φ8

2%

0.026

35.5

280

ACL-4.4V/600A

600

290*170*310

135/200*110-Φ8

2%

0.023

39.0

300

ACL-4.4V/660A

660

290*170*310

135/200*110-Φ8

2%

0.021

40.0

380

ACL-4.4V/800A

800

290*190*310

135/200*130-Φ8

2%

0.018

50.0

Ulanish sxemasi

13.png

Xizmatlashish shartlari

Balandlik — 1000 metrdan oshmasin.

Ishlash atrof-muhit harorati -25°C dan +45°C gacha,

Namlik 90% dan oshmaydi.

Atrof muhitda zararli gazlar, yonuvchi yoki portlovchi moddalar bo'lmasligi kerak.

Atrof hududda yaxshi ventilyatsiya ta'minlanishi kerak.

Agar kabinet ichiga o'rnatilsa, qo'shimcha ventilyatsiya jihozlari o'rnatilishi kerak.

Bepul taklif oling

Bizning vakilimiz tez orada siz bilan bog'lanadi.
Email
Ism
Kompaniya nomi
Message
0/1000

Bepul taklif oling

Bizning vakilimiz tez orada siz bilan bog'lanadi.
Email
Ism
Kompaniya nomi
Message
0/1000

Bepul taklif oling

Bizning vakilimiz tez orada siz bilan bog'lanadi.
Email
Ism
Kompaniya nomi
Message
0/1000