Rubutun Product
Reactor na kasa zai tsatse a karamin kasa don fayyade ne a cire harmoni na tashin da harmoni na karshen da yadda ya sa amfani da gida. Masu fasalin ACL/OCL sun bukatar shirin silikon mai kyau da kuma kayan aiki na musamman. Suna da karamin kasa mai ƙarfi, ƙarfi na yawa da kuma karamin kasa mai ƙarfi.
Kwayoyin da a saba su yi ne na iya haɗa da inverterin da alamarin daga wani kasa ko gaba daya, kamar Siemens, ABB, Sanken, Hitachi, Toshiba, Panasonic, Yaskawa, Powtran, Danfoss, Fuji, Eurotherm, LG, OMRON, Hyundai, Schneider, Lenze, Emerson da Convotherm.
Manyan siffofi
Takaddun na yadda ya zama mai ƙarfi (kara sauti & yadda mai ƙarfi) ga wasu abubuwa
Karamin yadda na kwayoyin da a saba su ya fi 1.8% na yadda mai ƙarfi
Kwayoyin da ke cikin karamin ƙarfi (karamin takaddun na kwayoyin da a saba su ya fi 10 kari da yadda mai ƙarfi na VFD)
Kwayoyin biyu ko ƙaranci na VFD an jarrabawa a cikin kwayoyin da a saba su don rage yadda na kwayoyin
Kapasitirin da ake amfani da su don rage yadda ko bayanin da ake amfani da su don rage yadda
Ƙididdigar fasaha
Karamin VFD (kW) |
Istilin takaddun na VFD |
Kudin Da Ajiye (A) |
Gaba daya na kwayoyin L*W*H (mm) |
Gaba daya na kwayoyin na jarrabawa L×W (mm) |
Karamin Kudura (m%) |
Inductance (mH) |
Kilogram (kg) |
2.2 |
ACL-4.4V/10A |
10 |
155*130*130 |
80/120x60-Φ8 |
2% |
1.401 |
3.5 |
5.5 |
ACL-4.4V/15A |
15 |
155*130*130 |
80/120x60-Φ8 |
2% |
0.934 |
3.6 |
7.5 |
ACL-4.4V/20A |
20 |
155*130*130 |
80/120x60-Φ8 |
2% |
0.701 |
3.6 |
11 |
ACL-4.4V/30A |
30 |
155*130*130 |
80/120x60-Φ8 |
2% |
0.467 |
3.7 |
15 |
ACL-4.4V/40A |
40 |
155*140*130 |
80/120x70-Φ8 |
2% |
0.350 |
5.1 |
18 |
ACL-4.4V/50A |
50 |
155*150*130 |
80/120x80-Φ8 |
2% |
0.280 |
6.0 |
22 |
ACL-4.4V/60A |
60 |
155*150*130 |
80/120x80-Φ8 |
2% |
0.234 |
6.1 |
30 |
ACL-4.4V/80A |
80 |
190*150*160 |
80/150x85-Φ8 |
2% |
0.175 |
9.0 |
37 |
ACL-4.4V/90A |
90 |
190*150*-160 |
80/150x85-Φ8 |
2% |
0.156 |
9.2 |
45 |
ACL-4.4V/120A |
120 |
190*160*160 |
80/150x95-Φ8 |
2% |
0.117 |
10.7 |
55 |
ACL-4.4V/150A |
150 |
230*150*220 |
120/180x85-Φ8 |
2% |
0.093 |
15.6 |
75 |
ACL-4.4V/200A |
200 |
230*150*220 |
120/180x85-Φ8 |
2% |
0.070 |
16.3 |
110 |
ACL-4.4V/250A |
250 |
230*160*220 |
120/180x95-Φ8 |
2% |
0.056 |
19.0 |
132 |
ACL-4.4V/290A |
290 |
265*180*250 |
135/200*90-Φ8 |
2% |
0.048 |
22.0 |
160 |
ACL-4.4V/330A |
330 |
265*190*250 |
135/200*100-Φ8 |
2% |
0.042 |
26.0 |
185 |
ACL-4.4V/390A |
390 |
265*190*250 |
135/200*100-Φ8 |
2% |
0.036 |
27.0 |
220 |
ACL-4.4V/490A |
490 |
290*160*310 |
135/200*100-Φ8 |
2% |
0.029 |
35.1 |
240 |
ACL-4.4V/530A |
530 |
290*160*310 |
135/200*100-Φ8 |
2% |
0.026 |
35.5 |
280 |
ACL-4.4V/600A |
600 |
290*170*310 |
135/200*110-Φ8 |
2% |
0.023 |
39.0 |
300 |
ACL-4.4V/660A |
660 |
290*170*310 |
135/200*110-Φ8 |
2% |
0.021 |
40.0 |
380 |
ACL-4.4V/800A |
800 |
290*190*310 |
135/200*130-Φ8 |
2% |
0.018 |
50.0 |
Tashin kofin

Service Conditions
Fadamar Altitute : ba tare da 1000 m.
Zamanin Aiki Na Gwamnati : -25°C ~ +45°C,
Namiji : ba taka da 90%.
Ba ake da gasai masu yawa, abubuwa mai kariya ko masu zama kariya a cikin wani baya.
Ya kamata a iya samun fahimtar hanyar gudunmawa a cikin wani baya.