Buod ng Produkto
Dapat i-install ang panlabas na reactor sa panlabas na terminal upang pumiloto ang harmonic voltage at harmonic current, at mapabuti ang kalidad ng power grid. Ang aming hanay ng pampasok at panlabas na reactor ay ginawa gamit ang mataas na kalidad na impiported na silicon steel sheets at advanced na craftsmanship. Nagtatampok ito ng kompakto at maliit na sukat, mababang temperature rise, at mababang ingay.
Ang mga reactor na ginagawa ng aming kumpanya ay maaaring i-match sa mga inverter ng lokal at internasyonal na brand tulad ng Siemens, ABB, Sanken, Hitachi, Toshiba, Panasonic, Yaskawa, Powtran, Danfoss, Fuji, Eurotherm, LG, OMRON, Hyundai, Schneider, Lenze, Emerson, at Convotherm.
Mga Pangunahing Tampok
Ang power supply ay nagdudulot ng malinaw na interference (ingay at sobrang voltage) sa iba pang kagamitan
Ang phase-to-phase voltage unbalance ng power supply ay lumalampas sa 1.8% ng rated voltage
Mga circuit na may napakababang impedans (ang kapasidad ng power transformer ay higit sa 10 beses ang rated value ng VFD)
Maraming VFD na nakainstala sa iisang circuit upang mabawasan ang line current
Mga capacitor para sa power factor correction o mga yunit ng PFC na nasa serbisyo
Mga teknikal na parameter
Power ng VFD (kW) |
Uri ng Input Reactor |
Nominadong Karagdagan ((A) |
Kabuuang Sukat L*W*H (mm) |
Sukat ng Pagkakalagay L×W (mm) |
Baba ng Ulat (%) |
Induktansya (mH) |
Timbang(kg) |
2.2 |
ACL-4.4V/10A |
10 |
155*130*130 |
80/120x60-Φ8 |
2% |
1.401 |
3.5 |
5.5 |
ACL-4.4V/15A |
15 |
155*130*130 |
80/120x60-Φ8 |
2% |
0.934 |
3.6 |
7.5 |
ACL-4.4V/20A |
20 |
155*130*130 |
80/120x60-Φ8 |
2% |
0.701 |
3.6 |
11 |
ACL-4.4V/30A |
30 |
155*130*130 |
80/120x60-Φ8 |
2% |
0.467 |
3.7 |
15 |
ACL-4.4V/40A |
40 |
155*140*130 |
80/120x70-Φ8 |
2% |
0.350 |
5.1 |
18 |
ACL-4.4V/50A |
50 |
155*150*130 |
80/120x80-Φ8 |
2% |
0.280 |
6.0 |
22 |
ACL-4.4V/60A |
60 |
155*150*130 |
80/120x80-Φ8 |
2% |
0.234 |
6.1 |
30 |
ACL-4.4V/80A |
80 |
190*150*160 |
80/150x85-Φ8 |
2% |
0.175 |
9.0 |
37 |
ACL-4.4V/90A |
90 |
190*150*-160 |
80/150x85-Φ8 |
2% |
0.156 |
9.2 |
45 |
ACL-4.4V/120A |
120 |
190*160*160 |
80/150x95-Φ8 |
2% |
0.117 |
10.7 |
55 |
ACL-4.4V/150A |
150 |
230*150*220 |
120/180x85-Φ8 |
2% |
0.093 |
15.6 |
75 |
ACL-4.4V/200A |
200 |
230*150*220 |
120/180x85-Φ8 |
2% |
0.070 |
16.3 |
110 |
ACL-4.4V/250A |
250 |
230*160*220 |
120/180x95-Φ8 |
2% |
0.056 |
19.0 |
132 |
ACL-4.4V/290A |
290 |
265*180*250 |
135/200*90-Φ8 |
2% |
0.048 |
22.0 |
160 |
ACL-4.4V/330A |
330 |
265*190*250 |
135/200*100-Φ8 |
2% |
0.042 |
26.0 |
185 |
ACL-4.4V/390A |
390 |
265*190*250 |
135/200*100-Φ8 |
2% |
0.036 |
27.0 |
220 |
ACL-4.4V/490A |
490 |
290*160*310 |
135/200*100-Φ8 |
2% |
0.029 |
35.1 |
240 |
ACL-4.4V/530A |
530 |
290*160*310 |
135/200*100-Φ8 |
2% |
0.026 |
35.5 |
280 |
ACL-4.4V/600A |
600 |
290*170*310 |
135/200*110-Φ8 |
2% |
0.023 |
39.0 |
300 |
ACL-4.4V/660A |
660 |
290*170*310 |
135/200*110-Φ8 |
2% |
0.021 |
40.0 |
380 |
ACL-4.4V/800A |
800 |
290*190*310 |
135/200*130-Φ8 |
2% |
0.018 |
50.0 |
Diagrama ng kable

Mga kondisyon ng serbisyo
Altitude : hindi lalampas sa 1000 m.
Operating Ambient Temperature -25°C hanggang +45°C
Halumigmig hindi lalampas sa 90%.
Walang nakakasirang gas, madaling sumabog o magsunog na mga bagay sa kapaligiran.
Dapat may sapat na bentilasyon sa paligid na lugar.
Kung naka-install sa loob ng isang kabinet, dapat may karagdagang kagamitan para sa bentilasyon.