Reactive power compensation device
Domus> Producta>Reactive power compensation device

BGMJ Cylindrical Self-healing Low Voltage Shunt Capacitor

Proprietates Claves

  • Compactus & Levis: Pondus tantum 1/4–1/5 ponderis productorum traditionalium, spatium pro installatione parcens et impensas pro transportando minuens.
  • Perdita Potentiae Parva: Perditio activa energiae minor est quam 1,2 W/kvar, ad efficacitatem energiae meliorandam et impensas operationis minuendas contribuens.
  • Praestantia Auto-Curativa Excellentissima: Cicatrizatio automatica celeris post disrutionem dielectricam partialem, quae ab overvoltatione vel overcurrente causatur, operationem continuam fidam assurans.
  • Potentior Protectio Contra Pericula : Equipatus resistori internae pro descarica et apparatu protectionis contra pressionem nimiam, ut operatio tutior et fidabilior sit.
  • Designatio sine effusione : Constructio hermetice clausa effugium efficaciter impedit, ut performantia longa, stabilis et fidabilis assuratur.
Descriptio Producti

Product Overview

BGMJ cylindrical self-healing low-voltage shunt capacitors apply to power factor correction for 50/60 Hz low voltage power systems, for local & centralized automatic compensation. It reduces reactive loss and optimizes voltage quality, a nationally recommended energy-saving product. Compliant with GB/T 12747 and IEC 60831-1/2.

Pelagus Technical Parametri

Voltage aestimatum : 0.23–1.14 kV

Capacitas aestimata : 1–60 kvar

Frequentia censita : 50 Hz or 60 Hz

Facultas Tolerantia : −3–5%

Amissa potentiae activae : ≤1.2 W/kvar

Voltage Withstand Between Poles : 2.15 Un for 5 seconds

Maxima Tolerabilis Supratensio : 1.1Un

Maxima Tolerabilis Supracurrentia : 1.3In Self-discharge

Characteristica : Tensio residua cadere debet ab √2Un ad minus quam 50 V intra 3 minuta post dismissionem condensatoris.

Normae Adimpletae : GB/T 12747, IEC 60831

Parametri technici

Typus BSMJ

Voltage aestimatum

(kV)

Capacitas aestimata

(kvar)

Capacitas Nominalis

(μF)

Currens nominalis

(Three/Single phase)(A)

Dimensio universa (mm)

Machinae Dimensio

Modellum

0.25-5-3YN(1)

0.25

5

255

6.7/20

φ76*240

M12

A/B

0.25-10-3YN(1)

0.25

10

510

13.3/40

φ86*240

M12

A/B

20/0.25-15-3YN(1)

0.25

15

764

20/60

φ106*240

M12

A/B

0.25-20-3YN(1)

0.25

20

1019

26.7/80

φ116*240

M16

A/B

0.25-25-3YN(1)

0.25

25

1274

33.3/100

φ116*240

M16

A/B

0.25-30-3YN(1)

0.25

30

1529

40/120

φ136*290

M16

A/B

0.45-5-3 (1)

0.45

5

79

6.4/11

φ76*240

M12

A/B

0.45-10-3 (1)

0.45

10

157

12.8/22

φ76*240

M12

A/B

0.45-15-3 (1)

0.45

15

236

19.2/33

φ86*240

M12

A/B

0.45-20-3 (1)

0.45

20

315

25.7/44

φ96*240

M16

A/B

0.45-25-3 (1)

0.45

25

393

32.1/56

φ96*290

M16

A/B

0.45-30-3 (1)

0.45

30

472

38.5/67

φ106*290

M16

A/B

0.45-40-3 (1)

0.45

40

629

51.3/89

φ116*290

M16

A/B

Dispositio electrica

8.png

Status servitii

Reclose Locking Protection: Post capacitor disconnection, re-energization is allowed only when residual voltage falls to 10% of rated voltage. Typical discharge time is approx. 200 seconds. Hence, controller incorporates a reclose locking timer to prevent premature switching.

Requisitum Rapidum Descaricandi: Cum controller conventionalis utitur, dispositivum additivum rapidum descaricandi requiritur. Hoc requisitum non applicatur cum commutatores commutationis equipotentialis adhibentur.

Altitudo: Idoneus pro installatione in altitudinibus usque ad 2 000 m.

Ambiens temperatus; −25°C ~ +50°C, temperatura media per 24 horas: ≤ +40°C, Temperatura media annualis: ≤ +30°C

Requisita Ventilationis: Capacitores in ambiente bene ventilato operari debent. Installatio et operatio in spatiis hermeticis vel pauca ventilatis prohibentur.

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Nomen societatis
Nuntius
0/1000

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Nomen societatis
Nuntius
0/1000

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Nomen societatis
Nuntius
0/1000