350-2500kVA 10KV 35KV Voltage Electrical Step-Down Electronic Three-Phase Pad Mounted Distribution Power Oil Immersed Transformer

Oil immersed series transformer


The fully sealed oil-immersed power transformer,  offers low loss, low noise, and high efficiency, ensuring energy-saving benefits and reduced pollution.

Unlike standard oil-immersed transformers, it eliminates the oil conservator, using a corrugated tank's elasticity to adjust oil volume automatically.

This design isolates the transformer from air, preventing oil and insulation degradation, enhancing reliability, and minimizing maintenance needs.

Product Description

Distribution transformer oil-immersed with power rating from 25 to 2500 kVA and Voltage 6-36/0,4 (0.23)kV. In 50/60 Hz power transmission and distribution system for power supply and lighting in industrial and agricultural field.

Distribution transformers are produced with nominal Voltage in primary winding 6 up to 36 kV. Nominal Voltage in secondary winding is 0,4 or 0,23 kV.

On the customer demand it is possible to make transformers with different connection of the Voltage s and other construction solution. Regulating the Voltage is made as a result of moving the switch, by the transformer detached from the net both high (HV) and low (LV) Voltages.


The Voltage is being regulated on the side of HV for ±2x2,5% value from nominal value. Exterior introductions HV and LV are removable and passers-by are made from China insulators.

At great current 1000 A and more on the hard core current are contact clamps screwed properly with the spatula which connecting the track or the cable attachment assures. The expandability of oil assures appropriate works of the transformer at different weather conditions and fluctuations of the temperature. The dehumidifier is installed to provide dry air in transformer. For measuring the temperature of upper layers of oil on the casing a thermometer is installed. Transformers with power rating from 400 to 2500 kVA are occupied with wells to install in base.

Power Capacity: 25-2500KVA

Voltage Level: 10KV,1IKV,13.8KV,15KV,17.5KV,20KV,22KV,24KV,30KV,33KV,35KV,36KV...... 132kv and Others as customers requirement

Type of Voltage Regulation: Off-circuit or On-load

Tapping Range: ±5 %±2x2.5 %±4x2.5 %

Frequency: 50Hz or 60Hz

Phases: Three or single

Connection Symbol: Dyn11,Yyn0 ( or as requested)

Short-circuit lmpedance: Standard lmpedance

Altitude is not exceeding 1000m,ambient temperature not exceeding 400C

If it can't meet such conditions,we will modulate parameters in accordance with standard.

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000