Reactive power compensation device
Domus> Producta>Reactive power compensation device

JKWF‑16S Automatic Reactive Power Compensation Controller

Proprietates Claves

  • Stabilis regulatio commutationis: Impedit oscillationem commutationis et certificat exactam commutationem capacitatis sub conditionibus harmonicis.
  • Exacta Mensura Factoris Potentiae: Latus ambitus mensurae et ostensionis.
  • 12 Codices Capacitatis Capacitorum: Selectio flexibilis pro variis applicationibus.
  • Usque ad 16 Circulos Exitus: Supportat compensationem flexibilem per fases separatas aut communem.
  • Modi Automaticus et Manualis: Includit functionem memoriae parametrorum.
  • Exitus Allarmi Programmabilis: Portus allarmis passivus facultativus cum eventibus allarmis seligendis.
  • Memoria post intermissionem: Parametri de controllo retinentur post interruptionem electricitatis.
  • Comprehensiva Protectio: Protectio contra tensionem nimis altam/bassam, harmonicas tensionis/currentis, et temperaturam nimis altam.
  • Latus ambitus adjustationis factoris potentiae: Regulatio factoris potentiae destinati flexibilis.
  • Interfacs communicandi facultativa: Supportat supervisionem et controllem remotam.
Descriptio Producti

Product Overview

JKWF series phase‑separated automatic reactive power compensation controller adopts high‑performance microprocessor as the core component. It samples three‑phase voltage and three‑phase current signals, with a maximum of 16 output loops. It supports full phase‑separated compensation, full common compensation, and combined common‑and‑phase‑separated compensation modes. Meanwhile, it provides 12 capacitor combination modes (capacity coding), which can be selected by users via modifying control parameters, and the settings are permanently saved after modification. It controls the switching of capacitor banks by combining fundamental power factor and fundamental reactive power, featuring stable switching without oscillation and low harmonic sensitivity. It can accurately display power data and perform switching control, and is applicable to automatic reactive power compensation control for 0.4 kV systems.

Parametri technici

Voltus Acceptabilis: AC220V±20% (3‑phase 4‑wire system)

Ratum est vena: AC0.1A‑5.5A; controller intrat in statum sub‑currentis cum currentus minor est quam 100mA

Frequentia Operativa: 45Hz‑65Hz

Sub limite voltage: 180V

Signum activum: DC12V, 10mA per canallem; terminalis communis positivus, outputus loopus negativus

Outputus passivus: Contactus relais, AC250V/3A

Signum alarmis: Outputus relais passivus, AC250V/3A

Consumptio electricitatis totalis: ≤10W

Protectio contra intrantia: IP30

Genus Connexionis: Screw-fixed socket-type terminal block

Modus Montandi: Flush mounting with bar-lock fasteners

Cut -out Dimension: 113mm*113mm

Dimensiones Totales: H122mm × W122mm × D99mm

Dispositio electrica

4.png

Status servitii

Altitudo: not exceeding 2500 m

Ambiens temperatus; -20 °C ~ 50 °C

Air humidity: ≤50 % at 40 °C, ≤90 % at 20 °C

No corrosive gas, conductive dust, flammable or explosive substances in surrounding environment

Nihil vibrationis gravis in loco installationis

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Nomen societatis
Nuntius
0/1000

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Nomen societatis
Nuntius
0/1000

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Nomen societatis
Nuntius
0/1000