Duk Kategori

Samu Kyautar Kyauta

Wakilinmu zai tuntube ku nan ba da jimawa ba.
Imel
Sunan
Sunan Shiga
Saƙo
0/1000

Samu Kyautar Kyauta

Wakilinmu zai tuntube ku nan ba da jimawa ba.
Imel
Sunan
Sunan Shiga
Saƙo
0/1000

Yaya a zaɓi transformer na bayani don project na microgrid

2026-11-02 16:20:39
Yaya a zaɓi transformer na bayani don project na microgrid

Zaɓin transformer na microgrid zai ƙasa daga wadannan project na bayani na yadda ake amfani da su. Ya kamata ya iya kawo PV, bayani na energy, chargers na EV da sauran abubuwan da ke amfani da electronics na kudada, da kuma kawo kudada akan biyu hanyoyi da kuma harmonics mai yawa. Idan transformer ya kashe, zai iya kawo kudada sosai da zai ci gaba. Idan ya fi ƙarfi, zai yi amfani da kudada sosai a lokacin da aka ba shi kudada sosai, kuma loss na kudada ba ta tabbata ba zai taimaka wajen kudada na kudada. Sudda uku na baya sun nuna yadda ake zaɓa.

1. Kudada: Ku saba ku saba kudada, sannan ku fahimci kuma kudada na kudada

Ba za a iya kara kudada na kudada na duk abubuwa ba. Wani formula mai lafiya shine:

Kudada ta saba = Kudada ta saba ta kudada

× Faktor na kudada ÷ Faktor na kudada

Faktor na kudada ya kashe 0.5–0.7don gida na factory na yadda ake amfani da su, 0.6–0.7don charging station na passenger vehicle, da 0.75–0.85don tashoshin caji mai sauri na manyan motoci. Ƙarfin ƙarfin yana yawanci a matsayin 0.9. Bayan lissafin sakamakon, zagaye zuwa ƙarfin daidaitaccen kuma ajiye 10%20% fadada maras kyau don ƙarin caji, PV modules ko sabon kaya.

Ƙididdigar ƙirar microgrid kuma ta ƙayyade cewa za a iya zaɓar ƙarfin mai canzawa bisa ga ƙarfin wutar lantarki mai ci gaba tsakanin microgrid da kuma waje grid, da kuma cewa kai-sanyaya, low-asara transformers ya kamata a fi son.

Ƙididdigar ƙididdiga na yau da kullum na iya zama mai sauri: 630 kVA don ƙananan PV da aka rarraba, wasu masu caji da iyakance kaya; 800 kVA don cajin ajiyar PV a matakin filin jirgin sama, tashoshin caji na matsakaici da PV na al'ada; 1250 kVA don caji mai sauri na manyan motoci, manyan matakan PV ko nodes tare da shirye-shiryen fadadawa. A cikin dogon lokaci, za a iya samun nauyin 70% 85%. Ka guji dogon lokaci na cikakken kaya ko tsawon lokaci a kasa da 50%.

2. Ka yi tunani a kan wannan. Voltage da Frequency: daidaita tare da Grid da Source-Side Kayan aiki

A ƙarfin lantarki matakin dogara a kan sharuddin da aikin grid ta hagu kuma dandamai na bayani na inverterin PV, ayyukan kariya PCS da chargers ta yanzu.

Kofigurashin mai kyau shi ne 10 kV katsin kariya ta hagu, 0.4 kV (380 V) katsin kariya ta yanzu, kuma 50 Hz . Idan PCS na kariya ta hawa 0.69 kV, katsin kariya ta yanzu zai kamata a zaune a 0.69 kV ba a gane 0.4 kV mai amfani sosai. Don mutum na vektor, Dyn11 ana amfani da ita sosai don transformerin da aikin 10 kV/0.4 kV. Ta tsaya harmonics na uku kamar yadda suka dace kuma ta yi aiki da loads da baya sosai, wanda ke dace da microgrids da harmonics manya.

3. Kuma ta Fidu ko Kuma ta Daga Ruwa: Ku Sani Muhimmancin Aiki na Kula da Kariya na Kashe Zuciya

Wannan shine kuma a matsayin masu amfani da shari'a , sannan yana da muhimmincin abin da ke cikin kudada da ala'adu.

Transformers mai gaba-gaban

Ba su da ruwa, suka dace da kula da kashe zuciya da suka dace da kula da kariya na kashe zuciya. Su dace da gida, gida ta hagu, gida ta yawa ko wani gida da kula da kashe zuciya ta fuskantarwa, kamar gida na tattalin arziki, hospitali, markazai na bayani da markazai na kariya ta zuciya na baya. Kudada na farko su ne 20%–30% yanzu daga kuma ta fidu na sauyin sama, amma don gida na dukkan lokaci kula da kashe zuciya shine abin da ya kamata su yi.

Transformaɗa mai kaiyayyaci

Yanzu daga kudada, su kara kariya daidai da su kara kariya mai kyau da su kara kariya mai kyau ga kariya ta yawa. Su iya kara kariya ta 120% ga wani lokaci ta yawa ba tare da kariya ba. Su dace da markazai na gaba daya, gida ta gaba da kula da kashe zuciya ta yawa, kamar gida na PV ta gaba, markazai na kariya ta gaba da markazai na kariya ta yawa na gaba daya. Masu kariya na farko kamar S22 suna da kariya mai yawa ta yawa da su kara kariya mai kyau ga kudada na kariya ta yawa.

A matsayin kukauni: dry-type don ya za a yi amfani da shi a cikin wajen da ke da yawa na mutane, kuma oil-immersed don ya za a yi amfani da shi a waje mai ƙarfi .

4. Losses, Temperature Rise and Impedance Voltage: Duba Kudin Ayyukan Daga Zaman Lafiya

Microgrid transformers suna gudan cikin lokaci mai yawa, don haka losses na no-load da load suna iya gyara kudin ayyukan daga zaman lafiya. Ya kamata a ji wa abubuwa da suka hada da GB 20052 kuma a sanya muhimmanci ga Grade 1 na energy efficiency. Misali, transformer na dry-type na 1000 kVA na Grade 1 zai iya gyara no-load loss ta hanyar 30% akan transformer na Grade 2. Kudin damar abubuwa na yanzu zai kashe a cikin 3 zuwa 5 shekara ta hanyar kudin elektrisitin da aka rage.

Zazzau Na Impedance don conventional distribution transformers shine ne a matsayin 4%–6%. Idan akwai mahaulluka biyu ko ƙarshen da suka gudan cikin parallel, farko na impedance voltage ba za a tace 10% ba. Yadda kuma temperature rise limits zai kamata su haɗa da GB 1094.2; temperature rise na winding shine ne ba za a tace 65 K ba. A wajen da ke cikin yanzu mai ƙarfi ko wajen da ke cikin kwalla, ya kamata a duba kuma gyara cooling system.

5. Haɗa da PV Inverters da Energy Storage PCS

Kuma transformer na gaba daya ya da shugaban yadda ake bayarwa. Transformer na microgrid ya da kuma uku daga cikin alalubarun da suka zuwa:

Matsayin farko, bayanin yadda ake bayarwa ta hanyar biyu. Yadda ake bayarwa zai iya canza akan dukkanin lokaci da suka zuwa da farko ko da biyu a cikin rana ta hanyar kariya ko ta fuskanta. Kuma tsarin kariya ya kamata a sani wadanda suka zuwa da kariya da fuskanta da kuma kariya da farko, ba tare da kariya ta hanyar gaba daya kamar yadda ake amfani da su a cikin gaba daya kuma.

Matsayin biyu, kuma kariya na harmonics. Inverters na PV da PCS na kariya na energy storage suna samu harmonics na 3rd, 5th da 7th, wadanda suka zama sababinsu na kariya mai yawa da kuma kariya na yankin da suka fi kuma yanzu. K-factor na transformer ya kamata a yi amfani da kuma kariya na K4. K4 ; lokacin da ake amfani da switching na high-frequency zai iya bukatar K13. Kuma impedance na short-circuit ya kamata a haɗa da manufacturers na PCS da inverters don gano resonance.

Matsayin uku, kuma kariya na overload na kariya na energy storage. Transformers na kariya na energy storage ana amfani da su a cikin kariya na 1-hour ta hanyar continuous discharge. Kuma kariya na short-time overload ya kamata a yi amfani da kuma kariya na margin; ba a yi amfani da kuma kariya ta hanyar one-to-one kamar yadda ake amfani da kuma kariya na PCS ta hanyar rated power.

6. Maballanin Fasaharri na Taimaka A Daga Kafin Samun

A cikin lokacin da aka kara gudummawa, kuma a ba maballanin fasaharri daga wannan shafi don zama yawa:

Paramituru Dabbobi

  • Kwayar fasaharri (kVA), fasaharri na ƙaramin/sauran yadda (kV), tashin yadda (Hz), hanyoyin, karamin karama (misali: Dyn11).

Ayyukan

  • Fasaharri na wani abu ba suka yi (kW), fasaharri na wani abu da suka yi (kW), karamin karama na fuskantar ( % ), karamin yadda na fuskantar (K), karamin karama na fuskantar, karamin karama na fuskantar.

Matsayin al'ada da karamin karama

  • Samun a cikin gida/cikin gida, karamin karama na fuskantar (fuskantar na cikin gida ba ta zama ƙasa da IP54), karamin karama na fuskantar, karamin karama na fuskantar, karamin karama na yadda.

Za su iya amfani da karamin karama na microgrid

  • Karamin karama na bidirectional operation, K-factor, karamin karama na harmonic spectrum ko karamin karama na PCS, karamin karama na short-time overload, karamin karama na grid-connection protection coordination.

Takaddun shaida

  • Karamin karama na energy efficiency test report, type test report, GB 20052 compliance certificate.

Karamin karama na Jiangsu Unita

Jiangsu Unita samfurin layin ya rufe bukatun zabin da ke sama:

  • Mai amfani da kayan aiki na kayan aiki na kayan aiki na kayan aiki na kayan aiki na kayan aiki na kayan aiki na kayan aiki na kayan aiki na kayan aiki na kayan aiki na kayan aiki na kayan aiki na kayan aiki na kayan aiki na kayan aiki na kayan aiki na kayan aiki na kayan aiki na kayan aiki na kayan aiki na kayan aiki na kayan aiki na kayan aiki na kayan aiki na Don tashoshin PV na waje, tashoshin bunkasa ajiyar makamashi masu zaman kansu da tashoshin caji a sararin samaniya. Nau'in nau'in nau'in nau'in nau'in nau'in nau'in nau'in nau'in nau'in nau'in nau'in nau'in nau'in nau'in nau'in nau'in nau'in nau'in nau'in nau'in nau'in nau'in nau'in nau'in nau'in
  • Ƙarƙashin ƙirar ƙirar ƙirar ƙirar ƙirar ƙirar ƙirar ƙirar ƙirar ƙirar ƙirar ƙirar ƙirar ƙirar ƙirar ƙirar ƙirar ƙirar ƙirar ƙirar ƙirar ƙirar ƙirar ƙirar ƙirar ƙirar ƙirar ƙirar ƙirar ƙirar ƙirar ƙirar ƙirar ƙirar ƙirar ƙirar ƙirar Don tashoshin caji na cikin gida, wuraren kasuwanci, cibiyoyin bayanai da kuma ɗakunan ajiya tare da tsananin bukatun kariya ta wuta. Ba tare da man fetur ba, mai saurin wuta, aji na 1 mai amfani da makamashi, kuma ya dace da yanayin yanayi na PV da kuma ajiyar makamashi na PCS.
  • Maganin da aka tsara: Tsarin da aka yi niyya don ƙarfin, rashin ƙarfi, haɓakar zafin jiki, ƙungiyar vector da ƙimar kariya bisa la'akari da ƙirar kaya, halayen PCS na jituwa, yanayin haɗin grid da kuma shirye-shiryen fadadawa. Muna kuma tallafawa masu kwangila da masu mallakar EPC tare da tabbatar da kaya da takardun haɗin grid.

180355c0-d88f-459c-802c-ab634c3edb91 (1).jpg

Teburin Abubuwan Ciki